Skip to content

Works of intervention

Retaining walls

To insert retaining walls on the slope proceeds as follows:

To delete a wall, choose the last of the three wall icons (wall with x sign on the left side) and click on the wall to delete.

It is possible to exclude the sliding surfaces that intercept the wall. In order to apply this condition, it is necessary to access the intervention panel and the window in which the wall geometry is characterised, choose the non-deformable type and do not select the automatic profile modification option. The result obtained is shown in the figure below.

If the automatic profile modification option is selected, the programme also considers sliding surfaces that interfere with the wall.

Anchors

To insert anchors proceeds as follows:

To change their position choose the Edit command (central icon) from the Intervention Works panel and position yourself on the wall to be moved, assign the new position in the Work Status frame displayed at the bottom of the panel.

To delete an anchor, choose the last of the three anchor icons (anchor with x sign on the left side) and click on the anchor to delete.

**Pilings

To insert piles proceeds as follows:

To change their position choose the Edit command (central icon) from the Intervention Works panel and position yourself on the wall to be moved, assign the new position in the Work Status frame displayed at the bottom of the panel.

To delete a pile, choose the last of the three pile icons (pile with x sign on the left side) and click on the pile to delete.